As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION AFT CARGO BAY FLOOR SPLICE STRAP AROUND NUT PLATE HOLE BS767+6' RBL11 WL156<[01] CORROSION AFT CARGO BAY FLOOR SPLICE STRAP AROUND NUT PLATE HOLE BS767+6' RBL11 WL156 FOUND TO BE OUT OF LIMITS DUE TO NO SRM ALLOWABLE LIMITS; REPLACEMENT OF PART REQUIRED IAW SRM 51-10-02-0G-0. RECEIVED NEW SERVICEABLE STRAP ON P.O. 889099/1. NEW STRAP WILL BE INSTALLED ON FAULT TTG8Q00P8BSZ.;[02] COMPLETE