As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT ENTRYWAY CENTER DROP DOWN PANEL EMERGENCY EXIT LIGHT IS BROKEN.<[01] UPDATED TABLE; SIGNED PART;[02] COMPLETED STEP 1;[03] COMPLETED STEP 2; REPLACED AFT ENTRYWAY CENTER DROP DOWN PANEL EMERGENCY EXIT LIGHT PER AMM 33-51-01-960-802; OPS CHECK IS GOOD.;[04] VERIFIED CORRECTIVE ACTION ENTRY 3. AND MEASUREMENT TABLE.