What was found
CORROSION ON MOP SILL UNDER FLOOR PANEL 242QF AT STA 867; RBL 64; WL 208. (MARKED)<[01] COMPLETED STEPS 1 AND 2.;[02] ADDED TOOL INFO. TO STEP 2.;[03] UPDATE STEP 4;[04] INSTALLED FOD/EWIS PROTECTION;[05] UPDATE STEP 7;[06] REMOVED CORROSION ON MOP SILL (CREASE BEAM INNER CHORD) UNDER FLOOR PANEL 242QF BS 867 RBL 46 WL 208; FOUND TO BE OUT OF LIMITS PER SRM 53-60-13-1A-1. REMOVED AND REPLACED INNER CHORD IAW SRM 51-40-02; DWG 146A5900 REV - AND DWG 147A0060 REV -;[07] VERIFIED CORRECTIVE ACTION 6;[08] VERIFIED CORRECTIVE ACTION 6 AND MEASUREMENT TABLE