What was found
AFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 727H-727I RBL 21.<[01] REMOVED CORROSION IAW SRM 51-10-02. MAT. REMOVED IS .009; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1.;[02] REMOVED CORROSION IAW SRM 51-10-02. MAT REMOVED IS .011. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1.;[03] REMOVED CORROSION IAW SRM 51-10-02. MAT REMOVED IS .011. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1.;[04] REMOVED CORROSION IAW SRM 51-10-02. MAT REMOVED IS .011. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2.;[05] CUT AND REMOVED R[12] REPAIRED RH SIDE PLATE STA 727G+10' TO 767; RBL 21 PER <BR>SRM 53-00-53-2R-5.;[13] VERIFIED REPAIRED RH SIDE PLATE STA 727G+10' TO 767; RBL 21 PER<BR>SRM 53-00-53-2R-5.;[14] PERFORMED SIDE PLATE NUTPLATE PUSH TEST PER SRM 51-40-10-2R-0.;[15] REPAIRED RH SIDE PLATE STA 727H-727I; RBL 21 PER SRM 53-00-53-1A-1 AND SRM 53-00-53-2R-5.;[16] REPAIRED RH SIDE PLATE STA 727H-727I; RBL 21 PER SRM 53-00-53-1A-2 AND SRM 53-00-53-2R-5. REFERENCE CORRECTED.;[17] INSPECTED WORK PERFORMED.