What was found
AFT PASSENGER COMPARTMENT FLOOR INTERCOSTAL JUST AFT OF FLOOR BEAM STA. 947 RBL 50; EVIDENCE OF CORROSION UNDER GALLEY TIE-DOWN FITTING.(MARKED) <BR>NOTE: PHOTO ATTACHED.<[01] REMOVED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF ALLOWABLE LIMITS PER SRM 53-70-51-1A-1;[02] STEP#1 C/W INSPECTION;[03] REMOVED INTERCOSTAL PER SRM 51-40-02 AND DRILL NEW INTERCOSTAL PER SRM 51-40-05.;[04] VERIFIED C/A #3.;[05] INSTALLED BONDED NUT PLATE PER SRM 51-40-10. 12/23/23 @@4:00 AM;[06] REMOVED GALLEY TIE-DOWN FITTING PER SRM 51-40-02.;[07] PERFORMED NUTPLATE PUSH TEST PER SRM 51-40-10-2R-0. NUTPLATES OK.;[08] VERIFIED C/A #5. TEKLU GEBREMARIAM (TECHNICIAN); 23-DEC-2023 10:24 UTC<BR>INSTALLED BONDED NUT PLATE PER SRM 51-40-10. 12/23/23 @@4:00 AM<BR><BR>INSPECTED WORK ACCOMPLISHED IN C/A #7. GEOFFREY SNYDER (TECHNICIAN); 24-DEC-2023 00:01 UTC PERFORMED NUTPLATE PUSH TEST; NUTPLATES OK; PER SRM 51-40-10-2R-0.;[09] REMOVED AND REPLACED INTERCOSTAL AT STA 947 RBL 50 PER SRM 51-40-02;[10] INSPECTED WORK PERFORMED