What was found
AFT CARGO COMPARTMENT FLOOR STRUCTURE; RIGHT SIDE PLATE HAS SURFACE CORROSION FROM STA 767-787 AROUND FASTENER HOLES.<[01] REMOVED CORROSION IAW SRM 51-10-02. MAT. REMOVED IS 0.010; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1;[02] REMOVED SIDE PLATE (SHIELD ASSY.) IAW SRM 51-40-02.;[03] REMOVED CORROSION IAW SRM 51-10-02. MAT. REMOVED IS 0.010; FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2;[04] DRILLED NEW RH SHIELD 146A8127U12 PER SRM 51-10-02 AND 51-40-02. OK TO INSTALL.;[05] INSPECTED THE WORK PERFORMED ON C/A #4; AND OK TO INSTALL R/H SHIELD.;[06] REJECT: QUESTION #1 RII IS INCORRECTLY ANSWERED AS NO AND SHOULD BE YES. <BR>SEE REJECTION BARCODE TTG8Q00QLDJ8;[07] C/W STEP 1;[08] INSTALLED RH SHIELD PER SRM 51-40-02.;[09] INSPECTED THE WORK PERFORMED ON C/A #1-#3 AND #7-#8; NO DEFECTS NOTED. <BR>COMPLIED WITH STEP 1; VERIFIED THE QUESTION #1 IS YES .;[10] CERTIFIED.