What was found
LIGHT CORROSION AT RT. GALLEY MOUNT FEET AT STA. 986 I/B AND O/B<[01] REMOVED CORROSION FROM R/H SHEAR WEB IAW SRM 51-10-02. DAMAGE REMOVAL OUT OF LIMITS IAW SRM 53-70-51-1A-1. CORROSION GOES COMPLETELY THROUGH .040 SHEAR WEB.;[02] PARTIALLY INSTALLED NEW WEB; (ALL FASTENERS LESS OUTBD ROW AND 3 OUTBD AFT FASTENERS PER SRM 41-40-02;[03] UPDATING CORRECTIVE ACTION 2. NICHOLAS AYLOR SRM REFERENCE TO; 'PARTIALLY INSTALLED NEW WEB; (ALL FASTENERS LESS OUTBD ROW AND 3 OUTBD AFT FASTENERS PER SRM 51-40-02'. SRM 41-40-02 WAS A TYPO.;[04] INSTALLED REMAINING FASTENERS IN NEW WEB P/N 147A5712U35 IAW SRM 51-40-02.;[05] VERIFIED CA#4 INSTALLED REMAINING FASTENERS IN NEW WEB P/N 147A5712U35 IAW SRM 51-40-02.;[06] SEE RAISED FAULT: CORRECTIVE ACTION #2 NEEDS INSP BUYBACK. CORRECTIVE ACTION #3 NEEDS CORRECTION TO BE DONE PER MPM AND INCLUDE MPM REFERENCE IN SIGN OFF. STEPS 1;2;3 NEED PARTIAL WORK TO BE DOCUMENTED BY AMT