What was found
CRACK FOUND AT LT HORIZONTAL STABILIZER LOWER SKIN STAB STA 193.90; CRACK LENGTH 0.750'; I/B OF I/B FASTENER ROW; 16.5' FROM L/E. CRACK FOUND AT LT HORIZONTAL STABILIZER LOWER SKIN STAB STA 193.90 CRACK LENGTH 0.750' I/B OF I/B FASTENER ROW 16.5' FROM L/E.<[01] COMPLETED SME INSPECTION OF WORKMANSHIP AND PAPERWORK AUDIT.;[02] INSTALLED HORIZONTAL STAB. LOWER IN SPAR SKIN REPAIR AT L/H HORIZONTAL LOWER SKIN AT STA. 193.90; PER REF. SRM 55-10-01-2R-22; THIS IS CATEGORY B REPAIR.; NEED INSPECTIONS THRESHOLD AT 56;000 TOTAL FLIGHT CYCLES; AND REPEAT INSPECTIONS INTERVAL AT 9;000 FLIGHT CYCLES;[03] RII....VERIFIED CORRECTIVE ACTION.