What was found
FWD CABIN FLOOR STRUCTURE BETWEEN STA 380 AND 400 RBL 8.5 WL 208.1 INTERCOSTAL UPPER FLOOR SUPPORT ANGLE IS CRACKED. 124-054<[01] REMOVED AND REPLACED NEW INTERCOSTAL UPPER ANGLE AT MAIN CABIN BETWEEN STA 380 TO 400 RBL 8.5 WL 208.1 MIXED TIME SEALANT 10:00AM SQUEEZE OUT 10:30AM SRM 51-40-02-0G-0 DWG 143A5400 AND AMM 51-31-00-390-801;[02] VERIFIED CORRECTIVE ACTION.