What was found
CORROSION ON FLOOR BEAM 986.5 LBL 42 WL 208.1 AT AFT GALLEY AREA 2023-786064<[01] EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 200053402; DUE DATE: 24-AUG-24.<BR><BR>ULTRASONIC THICKNESS GAGE P/N:45MG; S/N: 130060401; DUE DATE: 20-MAR-24.;[02] PERFORMED PERMANENT REPAIR ON FLOOR BEAM 986.5 LBL42 WL 208.1 IAW M-21-153-00612 . SEE INDIVIDUAL STEP SIGNOFF ON TTG8Q00QVEBU;[03] CORRECT STEP 2 : PERFORMED PERMANENT REPAIR ON FLOOR BEAM 986.5 LBL42 WL 208.1 IAW E.A M-21-153-00612 . SEE INDIVIDUAL STEP SIGNOFF ON TTG8Q00QVEBU;[04] CERTIFIED STEP 3 COMPLETED;[05] LATE ENTRY:<BR>CORROSION ON FLOOR BEAM 986.5 LBL 42 WL 208.1 AT AFT GALLEY ARE EVALUATED AND FOUND OUT OF LIMITS IAW B7373-700 SRM 53-70-51-1A-1 AD 1 PARAGRAPH 4 H (2)(B)1 FIG. 103 DETAIL E.;[06] CORRECTED STEP 5:<BR>LATE ENTRY:<BR>CORROSION ON FLOOR BEAM 986.5 LBL 42 WL 208.1 AT AFT GALLEY ARE EVALUATED AND FOUND OUT OF LIMITS IAW B737-700 SRM 53-70-51-1A-1 AD 1 PARAGRAPH 4 H (2)(B)1 FIG. 103 DETAIL E.;[07] CORRECTED STEP 4<BR>CERTIFIED STEPS 6 AND 3 COMPLETED <BR>TASK CARD COMPLETED