What was found
LH FWD CARGO SEC 1 AFT END FLOOR TO SIDEWALL SUPPORT CORRODED AROUND NUTPLATE HOLES BS 500A TO 500B; WL 150; RBL 20<[01] REMOVED CORROSION AT R/H FLOOR TO SIDE WALL SUPPORT; AREA FOUND OUT IF LIMITS IAW SRM 53-00-53-1A-2. FLOOR TO SIDE WALL SUPPORT GOING TO REPLACE ON TASK CARD TTG8Q00R9KAF;[02] VERIFIED STEPS 1;2; COMPLETE; MEASUREMENT TABLE COMPLETE; ACCOMPLISHED ON NRC TTG8Q00R9KAF; THIS CARD COMPLETE.