What was found
PANEL 140BF PANEL ASSEMBLY - AFT CARGO COMPARTMENT FLOOR HAS CORROSION AROUND FASTENER HOLES.<[01] REMOVED SURFACE CORROSION ON FASTENER HOLES ON FLOOR PANEL 140BF ATTACH PER SRM 51-10-02; FOUND TO BE WITHIN ALLOWABLE LIMITS. MATERIAL REMOVED 0.003 AND REMAINING THICKNESS 0.067. REPLACED COMPANY CONVENIENCE.;[02] CORRECTION FOR LINE 1. REMOVED SURFACE CORROSION ON FASTENER HOLES ON FLOOR PANEL 140BF ATTACH PER SRM 51-10-02; FOUND TO BE WITHIN ALLOWABLE LIMITS SRM 53-00-53. MATERIAL REMOVED 0.003 AND REMAINING THICKNESS 0.067. REPLACED COMPANY CONVENIENCE.;[03] CW INSP;[04] REMOVED AND REPLACED NEW FLOOR PANEL 140BF PER AMM 25-52-10.;[05] CORRECTION FOR LINE 4 INSTALLED NEW FLOOR PANEL 140BF ON TASK CARD TTG8Q00QFLH7