What was found
CORROSION INTERNAL STRUCTURE ZEE CHANEL SIDEPLATE LOCATED AT LEVEL OF STRINGER 25R AND BETWEEN STA 767 TO STA 794.37 AT AFT CARGO COMPARTMENT 2024-61214<[01] REPLACED ZEE CHANNEL SIDEPLATE LOCATED AT LEVEL OF STRINGER 25R AND BETWEEN STA 767 TO STA 794.37 AFT CARGO COMPARTMENT. IAW B737 800 SRM 51-40-02-0G-0; SRM 51-10-02 ITEM 9 AND DWG 146A0081 SHEET 46 REV -.SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED ZEE CHANNEL SIDEPLATE LOCATED AT LEVEL OF STRINGER 25R AND BETWEEN STA 767 TO STA 794.37 AFT CARGO COMPARTMENT. IAW B737 800 SRM 51-40-02-0G-0; SRM 51-10-02 ITEM 9 AND DWG 146A0081 SHEET 46 REV -.SEE INDIVIDUAL SIGN OFF BELOW.