What was found
CORROSION** AFT LOWER FUSELAGE TOILET SERVICE DOOR 145AL @ BONDING WIRE ATTACHED POINT MKD DOT<[01] REMOVED AND REPLACED CORRODED BONDING WIRE AT AFT LOWER TOILET SERVICE DOOR AS PER REF AMM 20-10-37-120-801.BONDING METER DUE DATE 13/MAR/24;[02] VERIFIED. REMOVED AND REPLACED CORRODED BONDING WIRE AT AFT LOWER TOILET SERVICE DOOR AS PER REF AMM 20-10-37-120-801.BONDING METER DUE DATE 13/MAR/24;[03] CORRECT MEASUREMENT TABLE QUESTION 3;[04] ENTRY'S NUMBER 1 & 2 WERE ENTERED IN ERROR.<BR> (PLEASE FOLLOW STEPS BELOW.);[05] SUMMARY :REMOVED BOUNDING WIRE FOR ACCESS AS PER SRM 51-40-02-0G-0.REMOVED CORROSION AFT LOWER FUSELAGE TOILET SERVICE DOOR AS PER 51-10-02-0G-0.PERFORMED UT THICKNESS INSP ON REWORKED AREA;<BR>IAW B737 NDT PART 4 51-00-00 PROC. 3<BR>TOOLS: 27MG; B/C 172139; CAL. DUE 30-MAR-2024. MIN. THICKNESS 0.046?.EVALUATED REWORKED AREA ORG MAT. 0.060 MAT REMOVED.014 MAT REMAINING 0.046 FOUND TO BE OUT OF LIMITS AS PER B 737 SRM 52-40-01-1A-4 REMOVED AND REPLACED ACCESS DOOR 145AL AS PER B 737 SRM 51-40-02-0G-0.;[06] NDT FINISHED