What was found
CORROSION FLOOR STRUCTURE WEB LOCATED BETWEEN BS 927 AND BS 947.5; LBL 24; WL 208.1 AT AFT GALLEY AREA 2024-69075<[01] TOOL USED UT EQUIPMENT P/N: 45MG; S/N: 130061901; CAL DUE DATE: 09-JUN-24;[02] TOOLS USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE 23 JAN 25; TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 112820025 DUE DATE 22 JAN 25.;[03] REPLACED ANGLE LOCATED ON FLOOR STRUCTURE LOCATED BETWEEN BS 927 AND BS 947.5; LBL 24; WL 208.1 AT AFT GALLEY ARE IAW B737-800 SRM 51-40-02 AND DWG 147A5400; SHEET 21; REV -. SEE INDIVIDUAL SIGNS-OFF BELOW.;[04] REPLACED ANGLE LOCATED ON FLOOR STRUCTURE LOCATED BETWEEN BS 927 AND BS 947.5; LBL 24; WL 208.1 AT AFT GALLEY ARE IAW B737-800 SRM 51-40-02 AND DWG 147A5400; SHEET 21; REV -. SEE INDIVIDUAL SIGNS-OFF BELOW.