What was found
R/H AFT EXTERIOR EMERGENCY LIGHT INOP<[01] RELAMPED R/H AFT EXTERIOR EMERGENCY LIGHT AND PERFORMED OPERATIONAL TEST PER AMM 33-51-04-960-801 AND LIGHT STILL NOT WORKING.;[02] CERTIFIED ACTION 1;[03] TROUBLESHOT PER FIM TASK 33-50 TASK 801 E.; G.; I. (D). ASSEMBLY REPLACEMENT NEXT STEP.;[04] PERFORMED A CONTINUITY CHECK OF L733 AFT R/H ESCAPE SLIDE AND ASSOCIATED WIRING PER WDM 33-51-14. WIRE W4142-0411-18 READS OPEN. UPON FURTHER INVESTIGATION FOUND CONNECTOR D11084 DISCONNECTED. CONNECTED D11084. PERFORMED A GOOD OPS TEST PER AMM SUBTASK 33-51-04-710-002;[05] VERIFIED CORRECTIVE ACTION ITEM 4 COMPLETE.;[06] UPDATED FOR MEASUREMENTS;[07] COMPLETED