What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BTW BS 344 TO BS 360 LBL 12 FWD GALLEY AND LAV 2024-78203<[01] REPLACED WEB - INTERCOSTAL AND FASTENERS LOC. FLOOR STRUCTURE BTW BS 344 TO BS 360 LBL 12 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DWG 141A5400 REV: A.;[02] CORRECTED STEP 1.<BR>REPLACED WEB - INTERCOSTAL AND FASTENERS LOC. FLOOR STRUCTURE BTW BS 344 TO BS 360 LBL 12 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DWG 141A5400 REV: A. SEE INDIVIDUAL SIGNOFF BELOW.;[03] CORRECTED STEP 2.<BR>REPLACED WEB - INTERCOSTAL AND FASTENERS LOC. FLOOR STRUCTURE BTW BS 344 TO BS 360 LBL 12 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DWG 141A5400; SHEET: 46; REV: A. SEE INDIVIDUAL SIGNOFF BELOW;[04] REPLACED WEB - INTERCOSTAL AND FASTENERS LOC. FLOOR STRUCTURE BTW BS 344 TO BS 360 LBL 12 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; SRM 51-10-02 PARAGRAPH 9 AND DWG 141A5400; SHEET: 46; REV: A. SEE INDIVIDUAL SIGNOFF BELOW