What was found
CRACK FRAME STA259.5 AT LEVEL STR 9R AT PASSENGER CABIN 2024-77317<[01] TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N: 200048001; DUE DATE: 01-MAY-24;[02] TOOL USED ULTRASONIC EQUIPMENT P/N 45MG; S/N 130066401 DUE DATE 05-OCT-24 USED ON STEP 9;[03] PERFORMED PERMANENT REPAIR LOC. ON FRAME STA259.5 AT LEVEL STR 5R TO STR 11R AT PASSENGER CABIN IAW EA-24-153-00353-WIP1 AND 24-153-00353-WIP2 SEE INDIVIDUAL SIGN-OFF BELOW;[04] PERFORMED PERMANENT REPAIR LOC. ON FRAME STA259.5 AT LEVEL STR 5R TO STR 11R AT PASSENGER CABIN IAW EA-24-153-00353-WIP1 AND 24-153-00353-WIP2 SEE INDIVIDUAL SIGN-OFF BELOW<BR>RII CERTIFIED