What was found
CRACK ON ANGLE FLOOR STRUCTURE LOCATED BTW BS 380 TO BS 400 LBL 13 AND WL 208 AT PASSENGER CABIN 2024-78497<[01] REPLACED ANGLE AND FASTENERS FLOOR STRUCTURE LOCATED BTW BS380 TO BS 400 LBL 13 AND WL 208 AT PASSENGER CABIN; IAW BOEING 737-700 SRM 51-40-02; BOEING 737-700 SRM 51-10-02 Ï¿½TEM 9; AND BOEING 737-700 DWG 143A5400 SHEET 38 REV A. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED ANGLE AND FASTENERS FLOOR STRUCTURE LOCATED BTW BS380 TO BS 400 LBL 13 AND WL 208 AT PASSENGER CABIN; IAW BOEING 737-700 SRM 51-40-02; BOEING 737-700 SRM 51-10-02 Ï¿½TEM 9; AND BOEING 737-700 DWG 143A5400 SHEET 38 REV A. SEE INDIVIDUAL SIGN OFF BELOW.