What was found
AFT CARGO COMPARTMENT FLOOR STRUCTURE; LEFT SIDE PLATE HAS SURFACE CORROSION FROM STA 727B-727C AROUND FASTENER HOLES.<[01] REMOVED CORROSIONS; REMAINING THICKNESS IS 0.034; OUT OF LIMITS IAW SRM 53-00-53-1A-2.;[02] REMOVED L/H SIDE PLATE PER SRM 51-40-02 FROM STA 727-847.;[03] OK TO INSTALL NEW SIDE PLATE.;[04] L/H SIDE PLATE IS REPLACED WITH NEW FROM STA 727 - 847. ALL WORK AND SIGN OFFS ACCOMPLISHED ON TASK CARD TTG8Q00RAMEJ;[05] WORK COMPLETED ON CARD TTG8Q00RAMEJ