What was found
CORROSION FOUND AT SECTION 2; LBL 21; BS 500-500C; WL 150 FAULT CORRECTION-CORROSION FOUND AT SECTION 2 AROUND NUTPLATE HOLES AT FLOOR TO SIDEWALL SUPPORTF<[01] REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT BETWEEN BS.396 - 500D; LBL21 WL 156.5 IAW B-737-700 SRM 51-40-02; SRM 53-00-53-2R-6 REPAIR 6 & DWG# 143A7500.;[02] UPDATE CORRECTIVE ACTIONS: REMOVED AND REPLACED FLOOR TO SIDEWALL SUPPORT BETWEEN BS.396 - 500D; LBL21 WL 156.5 AND (1EA.) SPLICE SIDEPLATE LOCATED AND BS. 480+10 IAW B-737-700 SRM 51-40-02; SRM 53-00-53-2R-6 REPAIR 6 & DWG# 143A7500.;[03] VERIFIED CORRECTIVE ACTION COMPLETE.<BR>VERIFIED MEASUREMENT TABLE.