What was found
AFT GALLEY LAV MOUNT HAS CORROSION AROUND BASE AT STA 947 LBL48.<[01] CLEAN CORROSION PER SRM 51-10-02. REWORKED AREA IS OUT OF LIMIT PER SRM 53-70-51-1A-1 DETAIL C.;[02] REJECT: FAULT CURRENTLY HAS 3 ISSUES:<BR><BR>1. MEASUREMENT #17; CORRODED ELEMENT PART NUMBER () HAS INCOMPLETE PART NUMBER LISTED.<BR><BR>2. MEASUREMENT #22 AND #23 ARE INCONSISTENT WITH OUT OF LIMITS FINDING IN CORRECTIVE ACTION #1.<BR><BR>3. THE CALIBRATED TOOLING LISTED ON THIS FAULT IS INCOMPLETE.<BR><BR>PLEASE SEE INSPRJCT PAUSE NOTES UNDER 'TASK INFORMATION' TAB FOR GUIDANCE ON THIS REJECTION.<BR><BR>**PLEASE NOTE THAT ALL CORRECTIONS MUST BE DONE ON ORIGINAL FAULT. INSPECTION WILL CLEAR REJECTION FAULT AFTER REJECTED TASK/FAULT HAS BEEN CORRECTED.**;[03] ASSIGNED CALIBRATED TOOLING AS REQUIRED. VERIFIED ALL MEASUREMENTS AND CORRECTED #17; 21; 22; AND 23 TO BE CONSISTENT WITH OUT OF LIMITS FINDING IN CORRECTIVE ACTION #1. REWORKED AREA IS OUT OF LIMITS PER SRM 53-70-51-1A-1; DETAIL C.;[04] INSPECTION CONFIRMS THAT REJECTION NOTED ON CORRECTIVE ACTION #2 HAS BEEN CORRECTED AS REQUIRED PER MPM 51.03.01 AND MPM 51.03.04.02. NO FURTHER ACTION REQUIRED. REJECTION FOUND FAULT CLEARED AT THIS TIME.;[05] REPAIR OF AFT GALLEY MOUNT CORROSION AT STA 947 LBL 48 HAS BEEN REPAIRED PER SRM 53-70-51-2R-5 ON FAULT # ID TTG8Q00RB9L0;[06] VERIFIED