As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY LIGHT POWER SUPPLY M1670 CONNECTOR DAMAGED<[01] REMOVED & REPLACED EMERGENCY LIGHT POWER SUPPLY (M1670) CONNECTOR. D10716P PER B737 SWPM 20-61-00 AND WDM 33-51-13 & 33-51-11 AND PERFORMED OPERATIONAL TEST OF THE EMERGENCY LIGHT POWER SUPPLY M1670 AS PER AMM 33-51-06-960-806. TEST PASSED;[02] VERIFIED STEP 1.