As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION FOUND AT SECTION 1; LBL 21; BS 440-500; WL 150 FAULT CORRECTION-CORROSION FOUND AT SECTION 1 AROUND NUTPLATE HOLES AT FLOOR TO SIDEWALL SUPPORT<[01] EVALUATED DAMAGE; WAS FOUND OUT LIMITS PER SRM 53-00-53-1A-2. STEP 4. (A) (2.A) FIG. 103.<BR> THIS CARD WILL BE ACCOMPLISHED ON TASK CARD TTG8Q00RBTEF.;[02] VERIFIED REPAIR WILL BE ACCOMPLISHED ON TASK CARD TTG8Q00RBTEF. VERIFIED MEASUREMENTS FIELDS. CARD COMPLETE