What was found
MAIN CABIN AFT WET AREA CORROSION AT AFT PRESSURE BULKHEAD SEAL STRAP RBL 33'<[01] CLEANED AFT WET AREA AT AFT PRESSURE BULKHEAD SEAL STRAP RBL 33' REF SOPM 20-30-03 AND TREATED AND APPLIED PRIMER AFT WET AREA AT AFT PRESSURE BULKHEAD SEAL STRAP RBL 33' REF AMM 51-21-41-370-803 AND 51-21-72-370-804 APPLIED CIC AT AFT PRESSURE BULKHEAD SEAL STRAP RBL 33' REF AMM 51-21-91-620-802;[02] INSP./ VERIFIED ENTRY #1 AS WORK ACCOMPLISHED.