What was found
GROUND POWER DOOR INTERNAL DOUBLER TORN;CRACK FWD LOWER CORNER<[01] ACCOMPLISHED PERMANENT REPAIR CATEGORY B AT EXTERNAL POWER RECEPTACLE CUTOUT AS PER B737-700 SRM 53-10-15-2R-5 REPAIR 5. REF TO STEP 13 FOR FURTHER INSPECTION REQUIREMENTS.;[02] VERIFIED FINAL STEP 1 RII;[03] REJECT....CORRECTIVE ACTION MISSING THRESHOLD FLIGHT CYCLES AND NDT FLIGHT CYCLES. CORRECTIVE ACTION BUYBACK TIMES DOES NOT MATCH; SHOULD BE LATE ENTRY. GENERATED TASK CARD [TTG8Q00RTN49];[04] -LATE ENTRY- IN ADDITION TO STEP 1: ACCOMPLISHED PERMANENT REPAIR CATEGORY B AT EXTERNAL POWER RECEPTACLE CUTOUT AS PER B737-700 SRM 53-10-15-2R-5 REPAIR 5. INSPECTION REQUIREMENTS AS FOLLOW: 50;000 CYC INSPECTION THRESHOLD; LFEC; HFEC AND DVI EVERY 6;000 CYC.;[05] VERIFIED STEP 4;[06] CERTIFIED WORK STEPS ACCOMPLISHED.