What was found
CRACK FLOOR STRUCTURE ON STUB FRAME LOCATED BS 294.5 AND S-17R AT FWD GALLEY AREA 2024-121461<[01] EDDY CURRENT EQUIPMENT USED P/N: NORTE 600D; S/N: 210138103 AND DUE DATE: 02-MAY-24.;[02] TOOL USED ON STEP 6: EDDY CURRENT EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101V022235; DUE DATE: 07-SEP-24;[03] PERFORMED REPAIR ON STUB FRAME LOCATED BS 294.5 AND S-17R AT FWD GALLEY AREA IAW B737-700 SRM 53-10-15-2R-7 REPAIR 7<BR>SEE INDIVIDUAL SIGNOFF BELOW;[04] TASK CARD COMPLETE AND CERTIFIED AS RII. <BR><BR><BR>SEE INDIVIDUAL SIGNOFFS BELOW.