What was found
CRACK ON FITTING LOCATED FLOOR STRUCTURE BS 947.5 AT LEVEL STR 26L AT AFT CARGO COMPARTMENT 2024-124169<[01] REPLACED FITTING LOCATED FLOOR STRUCTURE BS 947.5 AT LEVEL STR 26L AT AFT CARGO COMPARTMENT AND FASTENER IAW B737-700 SRM 51-10-02-0G-0 ITEM 9 AND SRM 51-40-02-0G-0 DWG 149A8103 REV A. SEE INDIVIDUAL SIGN OFFS BELOW.;[02] REPLACED FITTING LOCATED FLOOR STRUCTURE BS 947.5 AT LEVEL STR 26L AT AFT CARGO COMPARTMENT AND FASTENER IAW B737-700 SRM 51-10-02-0G-0 ITEM 9 AND SRM 51-40-02-0G-0 DWG 149A8103 REV A. VERIFIED