What was found
CRACK ON ANGLE LOCATED FLOOR STRUCTURE BTW BS 907 TO BS 927 AFT POSITION AND BTW STR 25R TO STR 27 AT AFT CARGO COMPARTMENT 2024-124170<[01] REPLACED ANGLE LOCATED FLOOR STRUCTURE BTW BS 907 TO BS 927 AFT POSITION AND BTW STR 25R TO STR 27R AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02-0G-0 AND DWG 147A7221 SHEET 24 REV -;[02] CORRECTED STEP 1<BR>REPLACED ANGLE LOCATED FLOOR STRUCTURE BTW BS 907 TO BS 927 AFT POSITION AND BTW STR 25R TO STR 27R AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02-0G-0; SRM 51-40-05 ; SRM 51-20-01 AND DWG 147A7221 SHEET 24 REV -;[03] REPLACED ANGLE LOCATED FLOOR STRUCTURE BTW BS 907 TO BS 927 AFT POSITION AND BTW STR 25R TO STR 27R AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02-0G-0; SRM 51-40-05 ; SRM 51-20-01 AND DWG 147A7221 SHEET 24 REV - RII VERIFIED