What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE AT LBL 12 AND BETWEEN BS344 TO BS360 AND WL 208.1 AT FWD GALLEY AREA 2024-124186<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE AND FASTENERS AT LBL 12 AND BETWEEN BS344 TO BS360 AND WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 141A5400 SHEET 46 REV A. SEE INDIVIDUAL SIGNOFFS BELOW.;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE AND FASTENERS AT LBL 12 AND BETWEEN BS344 TO BS360 AND WL 208.1 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9; SRM 51-40-02 AND DWG 141A5400 SHEET 46 REV A. RII VERIFIED