As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EXPANSION LINK FLOOR SUPPORT AT BS 520 RBL 2 WL 205 IS CRACKED. (MARKED) EXPANSION LINK FLOOR SUPPORT AT BS 540 RBL 2 WL 205 IS CRACKED<[01] REMOVED AND REPLACED EXPANSION LINK FLOOR SUPPORT AT BS 520 RBL 2 WL 205 I.A.W SRM 51-40-02-0G-0; IPC 53-31-00-05;[02] VERIFIED STEP 1 IN PARTIAL.;[03] VERIFIED ALL STEPS AND CORRECTIVE ACTION ITEMS; CARD COMPLETE.