What was found
FWD GALLEY SERVICE DOOR FIFTH BEAM CENTER SECTION BLIND FASTENER HAS SHREDDED<[01] REMOVED AND INSTALLED FASTENERS AT FWD GALLEY SERVICE DOOR FIFTH BEAM CENTER SECTION REF USED SRM 51-40-02-0G-0 STEP 4.B(1) AND DWG#141A5616;[02] VERIFIED R/R