What was found
CORROSION FLOOR STRUCTURE INTERCOSTAL LOCATED BTW STA 947.5 TO STA 967 AND LBL 50 WL 208.1 AT AFT GALLEY AREA 2024-165644<[01] REPLACED INTERCOSTAL LOCATED FLOOR STRUCTURE BTW STA 947.5 TO STA 967 AND LBL 50 WL 208.1 AT AFT GALLEY AREA IAW B737-800 SRM 51-10-02 PARAGRAPH 9 SRM 51-40-02 AND DRAWING 147A5650 SHEET 55 REV A<BR>SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED INTERCOSTAL LOCATED FLOOR STRUCTURE BTW STA 947.5 TO STA 967 AND LBL 50 WL 208.1 AT AFT GALLEY AREA IAW B737-800 SRM 51-10-02 PARAGRAPH 9 SRM 51-40-02 AND DRAWING 147A5650 SHEET 55 REV A.