What was found
CRACK ANGLE LOCATED BTW STA 380 TO STA 400 LBL 13.5 AT FWD GALLEY AREA 2024-165782<[01] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811020 DUE DATE: 23-JAN-25.TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811019 DUE DATE: 23-JAN-25.;[02] REPLACED ANGLE LOCATED FLOOR STRUCTURE BETWEEN BS380 TO BS400 AT LBL 13.5 AT FWD GALLEY AREA I.A.W. B737-800 SRM 51-40-02 AND DRAWING #143A5400; SHEET 140; REV-.<BR>SEE INDIVIDUAL SIGN OFFS BELOW.;[03] COMPLETE TASK CERTIFIED