What was found
GEAR RAISED NORMAL AFTER T/O. WHEN GEAR HANDLE LOWERED TO OFF NOSE GEAR EXTENDED WITH BOTH RED/GREEN NOSE GEAR LIGHTS ON. FOLLOWED QRH AND PUT GEAR HANDLE TO UP POSITION AND NOSE GEAR RETRACKED AND GEAR RAISED NORMAL AFTER T/O. WHEN GEAR HANDLE LOWERED TO OFF NOSE GEAR EXTENDED WITH BOTH RED/GREEN NOSE GEAR LIGHTS ON. FOLLOWED QRH AND PUT GEAR HANDLE TO UP POSITION AND NOSE GEAR RETRACKED AND LEFT THE GEAR HANDLE IN UP POSITION FOR REST OF FLIGHT.<[01] PERFORMED PSU BITE CK; NO FAULT HISTORY; PSU BITE CK GOOD NO FAULTS. PERFORMED NOSE GEAR SWING; NOSE GEAR AND NOSE LANDING GEAR INDICATION SYSTEMS OPS CK GOOD; NO FAULTS FOUND AS PER FIM 32-30-810; AMM 32-61-00; 07-11-21.