What was found
CRACK STIFFENER FLOOR STRUCTURE LOCATED BS540 BETWEEN BL 0 TO RBL 24.75 CENTER SECTION 2024-180645<[01] REPLACED STIFFENER FLOOR STRUCTURE LOCATED BS540 BETWEEN BL 0 TO RBL 24.75 CENTER SECTION IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 143A0060 SHEET:36 REV: A SEE INDIVIDUAL SIGNOFFS BELOW;[02] CERTIFIED STEP 1 COMPLETED