What was found
MULTIPLE EMERGENCY LIGHTS THROUGH A/C INSIDE CABIN AND EXTERIOR<[01] PERFORMED TROUBLESHOOTING FOR EMERGENCY LIGHTS AS PER B737 SSM 33-51-11; SSM 33-51-12 AND SSM 33-51-14; FOUND CONNECTOR D10750 AT EMERGENCY EXIT LIGHT POWER SUPLY M1675 NO PROPERLY SECURED; RESECURED CONNECTOR AS PER B737 AMM 33-51-06-960-806; SUBTASK 33-51-06-960-007; STEP (4); (F). CONTINUED TROUBLESHOOTING FOR EMERGENCY LIGHTS AS PER B737 SSM 33-51-11; SSM 33-51-12 AND SSM 33-51-14; FOUND LAMP (BULB) L733 AT AFT ESCAPE SLIDE BURNED UP; REPLACED LAMP AS PER B737 AMM 33-51-04-960-801. PERFORMED EMERGENCY LIGHTS - OPERATIONAL TEST AS PER B737 AMM 33-51-00-710-801. TEST PASS.;[02] VERIFIED STEP 1