What was found
AFT WET AREA FLOOR STRUCTURE INTERCOSTAL FROM STA 947.5 TO 967 AND RBL 25 IS CORRODED FLOOR STRUCTURE INTERCOSTAL FROM STA 947.5 TO 967 AND RBL 25<[01] REMOVED AND REPLACED INTERCOSTAL IN BETWEEN STA 947.5 AND 967 RBL 25 P/N 147A5660-3 REF BAC DWG 147A5650 AND B737NG SRM 51-40-02;[02] VERIFIED REMOVED AND REPLACED INTERCOSTAL IN BETWEEN STA 947.5 AND 967 RBL 25 P/N 147A5660-3 REF BAC DWG 147A5650 AND B737NG SRM 51-40-02