As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT WET AREA RIGHT HAND SIDE STATION 953 TO 963 FLOOR STRUCTURE CORRRODED<[01] REMOVED AND REPLACED FLOOR STRUCTURE INTERCOASTAL BETWEEN STA 947.5 AND 967 AND RBL 50.52 REQUIRES INSTALL. P/N 147A5660-22 REF BAC DWG 147A5650 AND B737NG SRM 51-40-02;[02] VERIFIED REMOVED AND REPLACED FLOOR STRUCTURE INTERCOASTAL BETWEEN STA 947.5 AND 967 AND RBL 50.52 REQUIRES INSTALL. P/N 147A5660-22 REF BAC DWG 147A5650 AND B737NG SRM 51-40-02