What was found
AFT CABIN WET AREA FLOOR INTERCOSTAL LBL-24 UPPER ATTACH ANGLE HAS CORROSION AT STA. 947 ATTACH POINT.<[01] REMOVED UPPER ATTACH ANGLE TO F.O.M AT LBL 24 IAW SRM 51-40-02.;[02] REMOVED CORROSION ON ATTACH ANGLE; MAT. REMOVED IS .004; MAT THICKNESS REMAINING IS 0.059; FOUND TO BE WITHIN LIMITS IAW SRM 53-70-51-1A-1.;[03] C/W INSPECTION OF CA #1 AND #2;[04] AFT CABIN WET AREA FLOOR INTERCOSTAL AT LBL 24 UPPER ATTACHED ANGLE REPLACED ON EA24-153-00664. LINE#2804 BARCODE: TTG8Q00S5KFB.;[05] C/W INSPECTION;[06] C/W INSPECTION