What was found
FWD CARGO STA. 485 RBL 31; CORROSION ON ENTRY DOOR THRESHOLD WEB PANEL.<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .015?. DAMAGE FOUND TO BE OUT OF LIMITS I.A.W SRM 53-30-15-1A-1.;[02] REMOVED LOWER THRESHOLD WEB PANEL I.A.W. SRM 51-40-02.;[03] DRILL AND COUNTERSUNK NEW WEB IAW SRM 51-40-05 AND SRM 51-40-08. <BR>NEED OK TO INSTALL.;[04] OKAY TO INSTALL NEW LOWER THRESHOLD WEB FOR THE FORWARD CARGO DOOR OPENING.;[05] INSTALLED FWD CARGO DOOR THRESHOLD NEW WEB IAW SRM 51-40-02.;[06] VERIFIED C/A # 3 : TEKLU GEBREMARIAM (TECHNICIAN); 21-MAR-2024 03:37 UTC<BR>DRILL AND COUNTERSUNK NEW WEB IAW SRM 51-40-05 AND SRM 51-40-08.;[07] VERIFIED C/A # 5 : TEKLU GEBREMARIAM (TECHNICIAN); 21-MAR-2024 07:48 UTC<BR>INSTALLED FWD CARGO DOOR THRESHOLD NEW WEB IAW SRM 51-40-02.