What was found
FWD CARGO TRACK TIE DOWN HAS CORROSION AT BS 480+17; LBL 19; WL 156<[01] UPDATED PART REQUIREMENTS.;[02] REMOVED AND REPLACED FCB FLOOR TRACK FROM BS 396 TO BS 500D; LBL 19; WL 156 IAW SRM 51-40-02-0G-0 AND DWG# 143A7500;[03] VERIFIED
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO TRACK TIE DOWN HAS CORROSION AT BS 480+17; LBL 19; WL 156<[01] UPDATED PART REQUIREMENTS.;[02] REMOVED AND REPLACED FCB FLOOR TRACK FROM BS 396 TO BS 500D; LBL 19; WL 156 IAW SRM 51-40-02-0G-0 AND DWG# 143A7500;[03] VERIFIED