What was found
DETERIORATE GIRT BAR FITTING PLATE (4EA) AND SHIM (4EA) ON POSITION SERVICE DOOR AND ENTRY DOOR AT AFT GALLEY AREA 2024-206212<[01] REPLACED GIRT BAR FITTING PLATE (4EA) AND SHIM (4EA) ON POSITION SERVICE DOOR AND ENTRY DOOR AT AFT GALLEY AREA IAW SOPM 20-50-01;[02] REPLACED GIRT BAR FITTING PLATE (4EA) AND SHIM (4EA) ON POSITION SERVICE DOOR AND ENTRY DOOR AT AFT GALLEY AREA IAW SOPM 20-50-01