What was found
CORROSION CREASE BEAM LOCATED STA639 AND LBL64.5 WL208.1 CENTER SECTION 2024-195750<[01] REPLACED CREASE BEAM LOCATED STA616 PLUS 10 IN TO STA639 PLUS 10IN AND LBL64.5 WL208.1 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DWG 144A5901 REV:- SEE INDIVIDUAL SIGN OF BELOW;[02] CORRECTED ACTION 1<BR>REPLACED CREASE BEAM LOCATED STA 616 PLUS 10 INCHES TO STA 639 PLUS 10 INCHES AND LBL 64.5 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DWG 144A5901 SHEET 36 REV:- SEE INDIVIDUAL SIGN OFF BELOW;[03] REPLACED CREASE BEAM LOCATED STA 616 PLUS 10 INCHES TO STA 639 PLUS 10 INCHES AND LBL 64.5 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DWG 144A5901 SHEET 36 REV:- SEE INDIVIDUAL SIGN OFF BELOW AS RII