What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED STA540 BETWEEN RBL24.75 TO RBL45.5 CENTER SECTION 2024-195747<[01] REPLACE ANGLE FLOOR STRUCTURE LOCATED STA540 BETWEEN RBL24.75 TO RBL45.5 CENTER SECTION IAW. B737-700 SRM 51-40-02-0G-0 AND DRAWING 143A0060;[02] INSTALLED NEW ANGLE FLOOR STRUCTURE; PERFORMED VISUAL INSPECTION AND NOT FOUND ADDITIONAL DAMAGE LOCATED STA540 BETWEEN RBL24.75 TO RBL45.5 CENTER SECTION IAW. B737-700 SRM 51-40-02-0G-0 AND DRAWING 143A0060;[03] COMPLETED JOB