What was found
CRACK WEB FLOOR STRUCTURE LOCATED BETWEEN STA500D TO STA520 AT LEVEL STR28R AT FWD CARGO COMPARTMENT 2024-195808<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 22-JAN-25; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 22-JAN-25.;[02] REPLACED WEB FLOOR STRUCTURE AND FASTENERS LOCATED BETWEEN STA 500D TO STA 520 AT LEVEL STR 28R AT FWD CARGO COMPARTMENT I.A.W. B737-700 SRM 51-40-02-0G-0;SRM 51-10-02-0G-0 Ï¿½TEM 9 AND DWG 143A7902 REV:A SEE INDIVIDUAL SIGN OFF BELOW.;[03] REPLACED WEB FLOOR STRUCTURE AND FASTENERS LOCATED BETWEEN STA 500D TO STA 520 AT LEVEL STR 28R AT FWD CARGO COMPARTMENT I.A.W. B737-700 SRM 51-40-02-0G-0;SRM 51-10-02-0G-0 Ï¿½TEM 9 AND DWG 143A7902 REV:A SEE INDIVIDUAL SIGN OFF BELOW. JOB COMPLETED.