What was found
AFT WET AREA- CORROSION ON FLOOR WEB AT STA 986 +3; LBL +33 MARKED; BLENDED CORROSION PER SRM 51-10-02. REMOVED .030' OF MATERIAL. REMAINING THICKNESS IS .010'. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-70-51-1A-1. BLENDED CORROSION PER SRM 51-10-02. REMOVED .030' OF MATERIAL. REMAINING THICKNESS IS .010'. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-70-51-1A-1.;REMOVED DAMAGED WEB FROM STA. 986.5 TO STA. 1016; LBL 30' TO LBL 46' PER SRM 51-40-02.;[04] LOCATED AND DRILLED NEW SHEAR WEB PER SRM 51-40-05. OK TO INSTALL PER SRM 51-40-02. INSPECTED REMOVAL OF WEB & LOCATION & DRILL OF NEW SHEAR WEB PER SRM 51-40-05. OK TO INSTALL (RII);[06] RII-INSTALLED NEW SHEAR WEB FROM STA. 986.5 TO STA. 1016; LBL 30? TO LBL 46' PER SRM 51-40-02. APPLIED EDGE SEAL AND CAP SEAL PER AMM 51-31-00.