What was found
AFT WET AREA- CORROSION ON FLOOR PAN WEB AT STA 1006 +3; LBL +38. DRILLED UP NEW WEB PER SRM 51-40-02.;[02] BLENDED CORROSION ON FLOOR PAN WEB AT STA. 1006+3'; LBL 38' IAW SRM 51-10-02. REMOVED .012' OF MATERIAL. REMAINING THICKNESS IS .028. DAMAGE REMOVAL OUT OF LIMITS PER SRM 53-70-51-1A-1.