As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD CARGO FLOOR STRUCTURE SIDE PLATE HAS LIGHT CORROSION AROUND FASTENER HOLES FROM STA 500 TO 500A RBL 24.<[01] BLENDED AREAS; REMOVED .030' MATERIAL. FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] REMOVED AND REPLACED SHIELD PER SRM 51-40-02.;[03] 02 - INSPECTED PER [SRM 51-40-02-0G-0-B00069 (GENERAL - FASTENER INSTALLATION AND REMOVAL - AIRFRAME - PERMANENT)]