What was found
STA 986.5 FLOOR BEAM UPPER FLANGE HAS CORROSION AROUND FLOOR PANEL ATTACH HOLE AT LBL 30.5.<[01] BLENDED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. ORIGINAL THICKNESS=.150?; REMAINING THICKNESS=.125?.;[02] BLENDED CORROSION PER SRM 51-10-02. DAMAGE REMOVAL FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. ORIGINAL THICKNESS=.150?; REMAINING THICKNESS=.125?;[03] TSR 2024002406 SUBMITTED;[04] REPAIRED PER SRM 53-70-51-2R-6;[05] 02 - INSPECTED PER [SRM 53-70-51-2R-6-B00676 (REPAIR 6 - SECTION 47 - SMALL CORROSION DAMAGE ON THE UPPER CHORD OF THE FLOOR BEAM AT STA 986.5 - PERMANENT)];[06] 02 - INSPECTED PER [SRM 53-70-51-2R-6-B00676 (REPAIR 6 - SECTION 47 - SMALL CORROSION DAMAGE ON THE UPPER CHORD OF THE FLOOR BEAM AT STA 986.5 - PERMANENT)]